HOME > Home Storage System > Solar Inverter >

HBF5000 5.0KW Off Grid Energy System

Item Code: HBF5000
Max PV Power Input: 3000W
Maximum Efficiency: 98%
Mppt Voltage Range: 60~115V DC
Grid Input(AC): 230/211~264VAC 50Hz
Rated Battery Volatge: 48VDC
Battery Voltage Range: 40V~58V
AC Voltage Regulation Output: 230V
Surge Power: 6000VA

Brand  :      DARFON
Description
INTRODUCTION
This is a multi-function off grid energy system, combining functions of inverter, solar charger and battery charger to offer uninterruptible power support with portable size. Its comprehensive LCD display offers user-configurable and easy-accessible button operation such as battery charging current, AC/solar charger priority, and acceptable input voltage based on different applications.

Features
 *Pure sine wave inverter
 *Integrated MPPT charger controller
 *Configurable input voltage range for home appliances and personal computers via LCD setting
 *Configurable battery charging current based on applications via LCD setting
*Configurable AC/Solar Charger priority via LCD setting
*Compatible to mains voltage or generator power
*Auto restart while AC is recovering
*Overload/ Over temperature/ short circuit protection
*Smart battery charger design for optimized battery performance
*Cold start function

Basic System Architecture
The following illustration shows basic application for this off grid energy system. It also includes following devices to
have a complete running system:
      *Generator or Utility.

      *PV modules (option)
Consult with your system integrator for other possible system architectures depending on your requirements.

This inverter can power all kinds of appliances in home or office environment, including motor-type appliances such as tube light, fan, refrigerator and air conditioner.





Note: Appliances like air conditioner need at least 2~3 minutes to restart because it’s required to have enough time to balance refrigerant gas inside of circuits. If a power shortage occurs and recovers in a short time, it will cause damage to your connected appliances. To prevent this kind of damage, please check manufacturer of air conditioner if it’s equipped with time-delay function before installation. Otherwise, this off grid energy system will trig overload fault and cut off output to protect your appliance but sometimes it still causes internal damage to the air conditioner.

Display Panel



Invert Mode Specifications

INVERTER MODEL  HBF5000
Rated Output Power  5KVA/4KW
Output Voltage Waveform  Pure Sine Wave
Output Voltage Regulation  230Vac±5%
Output Frequency  60Hz or 50Hz
Peak Efficiency  90%
Overload Protection  5s@≥150% load; 10s@110%~150% load
Surge Capacity 2*  2*rated power for 5 seconds
Nominal DC Input Voltage  48Vdc
Cold Start Voltage  46.0Vdc
Low DC Warning Voltage  
@ load < 20%
@ 20% ≤ load < 50%
@ load ≥ 50% 
44.0Vdc
42.8Vdc
40.4Vdc
Low DC Warning Return Voltage  
@ load < 20%
@ 20% ≤ load < 50%
@ load ≥ 50% 
46.0Vdc
44.8Vdc
42.4Vdc
Low DC Cut-off Voltage  
@ load < 20%
@ 20% ≤ load < 50%
@ load ≥ 50% 
42.0Vdc
40.8Vdc
38.4Vdc
High DC Recovery Voltage 58Vdc
High DC Cut- off Voltage 62Vdc
No Load Power Consumption  <50W
Saving Mode Power Consumption  <15W

Charge Mode Specifications
INVERTER MODEL  HBF5000
Utility Charging Mode  
Charging Current (UPS) 20/30Amp 
Bulk Charging Voltage 
Flooded Battery
AGM/Gel Battery

58.4Vdc
56.4Vdc
Charging Floating Voltage  54Vdc
Charging Algorithm 3-Step
Solar Charging Mode  
Rated Power  3000W
Efficiency  98.0% max.
Max. PV Array Open Circuit Voltage  145V max.
PV Array MPPT Voltage Range  60V~115V
Min battery voltage for PV charge  34Vdc
Standby Power Consumption  2W
DC Voltage Accuracy  +/-0.3%
PV Voltage Accuracy +/-2V
Charging Algorithm 3-Step


General Specifications
INVERTER MODEL HBF5000
Safety Certification CE
Operating Temperature Range 0°C to 55°C
Storage temperature -15°C~ 60°C
Dimension (D*W*H), mm 140 x 295 x 540
Net Weight, kg 13.5



Inquiry Details

If you have any questions relating to any of our products or serivces,pls feel free to contact us. A sales Representitive will get back to you in 8 hours.

Name Email TEL Country Subject: Messages VCode : unclear? click pic to changeAuthCode.