HOME > Home Storage System > Lithium Storage Battery >

600W Off -Grid Modified Wave Home Power

Features

 

* Wall-hung UPS for Home Power. 
* Built in a big capacity Lithium battery,Back up 4 hours for 100W general home ligting and wifi power.
* Once installed , the unit be used everyday not only under no grid. 
* Auto start grid or battery while AC is off or recovering 
* Convertable Utility Grid/ UPS offer power via By Pass switch 
* 600W Full power design inverter, infinitely extendsible standby power." 
* Input voltage error alarm, shutdown protection function. 
* LCD screen display UPS status : Grid or Battery 
* LED lights and buzzing alarm: battery low , over- heat, over- load and shutdown" 
* Pull In/output plugs out from the wall directly, Convenient to maintain and repair .

 

 


 

 

Description

Product Video:
https://youtu.be/7k87HhgqbkY



Features

 

* Wall-hung UPS for Home Power. 
* Built in a big capacity Lithium battery,Back up 4 hours for 100W general home ligting and wifi power.
* Once installed , the unit be used everyday not only under no grid. 
* Auto start grid or battery while AC is off or recovering 
* Convertable Utility Grid/ UPS offer power via By Pass switch 
* 600W Full power design inverter, infinitely extendsible standby power." 
* Input voltage error alarm, shutdown protection function. 
* LCD screen display UPS status : Grid or Battery 
* LED lights and buzzing alarm: battery low , over- heat, over- load and shutdown" 
* Pull In/output plugs out from the wall directly, Convenient to maintain and repair .

Specification:

 

MODEL DPU-24060C

Inverter

Output

Rated Power 600W ±3%  continous Power
Peak Power 1200W
Rated  voltage 220V ±5%( No-Load)
Frequency 50HZ ±1% 
Wave Modified Wave 220Vrms Vpk=280V
Lowest Output Voltage 196Vac(Bat.20V)
Converting  (Grid->Battery) < 36ms 
Converting  (Battery->Grid) < 13ms
DC Input Input Voltage(Vdc) 24V(20V~31.2V)
No-Load Current(under Bat.>25V) < 0.15A
Efficiency(Full Load) >85%
Battery Low Voltage Alarm( No Load) 21.0V ± 0.3V
Battery Low Voltage  Cut off 20.0V ± 0.3V 
Auto power on Voltage (After BLV off) 25.0V ± 0.3V 
Battery High Voltage Cut off 32V

AC Input

(NO AVR)

Input Voltage Range(Vac) 200~240V 
AC Input Protection 5A Fuse on the Machine Bottom
AC Low Voltgae Detection(Vac) AC <20V trasfer to Battery Mode
AC > 160V recover to AC Mode
 
AC High Voltgae Detection(Vac) NO
Efficiency(Full charging) 87.50%

Charger

Output

Output Voltage 29.2V(No Load) ±0.15V 
Charging Current 3.5A ±0.15A
Charging Voltage 29.4V
Charging (battery) protection  when the battery capacity dwon to 92.5%  after full charged, the charger will automatic re-charging the battery
Over Voltage Protection 29.4V+0.35V
Battery Rated  Voltage 24V
Capacity 480Wh
Battery Type Lithium
Battery Cell Samsung Cell

Inverter

Protction

Battery Polarity Reverse Protection Internal Fuse
Fan Starting Internal Temperature >42℃  Fan Starting ,<40℃ Stop Fan Stopping
Over Heat Alarm Int Temp >69℃  Buzzing,<63℃ Buzzing Stop.
Over Heat  Cut off  Int Temp >78℃ Cut off, Re-start after 10secs.
Over Load Protection Load >100%  Alarm 5 secs,>110% Alarm 3secs ,>120% Cut off,
Remove Over Load , Auto on after 10 secs.
Short Circuit Protection   Load>150%  or Short Ciruit , the Machine power off .

Alarm &

Display

Buzzer Battery Low Voltage( Beep) , Over Heat( Beep Beep) , Over Load(Beep Beep Beep) and Cut off(Beeeee)
LCD 1.NORMAL(AC-LINE) ,BATTERY(Inverter) ,CHARGER
  Battery Capacity display  25%,50%,75%,100%
LED Working LED:  Green =AC-LIN,Red=Battery, 
  Alarm LED : Red flash =Battery low , Yellow flash= Over Heat 
  Yellow = Over Heat cut off   Red = Over Load Cut off 
 ENVIRONMENT Working Temperature -20 ~ 60 ℃  
Working Humidity 20 ~ 90% RH non-condensing
Storage Temperature and Humidity  18~  28 ℃ , 10 ~ 95% RH
vibration  10 ~ 500Hz, 2G 10min./1cycle
 SAFETY & EMC Certificate IEC62040
OTHERS Unit Dimension 357mm(L)*330mm(W)*113mm(H)
Unite  Net Weight 9.0 kg
Package 1 Set/ Box   2 box/Ctn  
  NOTE * This unite must be used in the room with well ventilated  and less dust
* The load >10uF AC capacitor and pumping motor (inductive load), which can't be used.  

 This specification is subject to change without notice 

 

Basic System Architecture

 









Product Q&A

1. Q: Can it be used in our office?
A: Yes. However, if the daily power consumption of the office exceeds 600w, after the installation is completed, the transfer switch should be switched to the grid or the mains for normal use of the electricity. When a power outage occurs (where the UPS will sound a beep), you may use the Home Power UPS to maintain
emergency power supply for lighting, servers, Wi-Fi, etc. In order to avoid overload, the total load shall not exceed 600w.


2. Q: Can it drive the refrigerator?
A: The DPU-24060C model cannot be used to serve the purpose in question. Generally, the power consumption of the refrigerator is more than 2000w, and the starting current is large. So, The DPU-24060C model cannot be used to serve home appliances such as the hair dryer. However, in the series of products, there
are models that can drive the refrigerator, so stay tuned.


3. Q. My house uses incandescent lamp, energy-saving lamp and LED lamp. Can the product apply to all of them?
A: It is best to use high-quality LED lights with the PF value > 0.8

4. Q: Can I install it myself? Is it usable right after it’s plugged in to the outlet?
A: No. The input terminal of the unit can be connected to any of the sockets in the house. However, the output terminal and the transfer switch need to be installed strictly by professionals according to the installation instructions to prevent damages to the unit from happening.

5. Q: My home has not been renovated. The electricity distribution system is old. Can I still use this product in my house?
A: Yes, same as the answer to Question 1.


Inquiry Details

If you have any questions relating to any of our products or serivces,pls feel free to contact us. A sales Representitive will get back to you in 8 hours.

Name Email TEL Country Subject: Messages VCode : unclear? click pic to changeAuthCode.

TOP